Technical features of J5000 Ozone Monitor product
Product technical features
Test method: Dual-path ultraviolet light absorption method, long-life light source system, high measurement accuracy.
Measurement principle: Based on Lambert-Beer's law, it accurately measures through the principle of photometric absorption. :
Light source system: Long-life ultraviolet light source system (wavelength: 253.7nm)
Usage method: Indoor installation and use, equipped with power and signal terminals.
Optical cell system: Split optical cell technology, no leakage, high pressure resistance, and resistant to the impact of large flow sampling gas.
Intelligent compensation: Built-in temperature and pressure compensation and display, with automatic light source compensation function. :
Operation mode: Users can choose between manual zeroing and automatic zeroing based on the running status, and can set the time for automatic zeroing.
Display unit: High-definition color touch screen, high-concentration range setting for the mass flow rate of the incoming gas, real-time display of production volume.
The data shows that g/Nm3, mg/NL, %WT, ppm, and mg/Nm3 are optional.
Output functions: 4-20mA, RS485: communication, two groups of alarm point output, electronic flowmeter input, etc.
Standard configuration: Anti-corrosion flowmeter, ozone tail gas destructor.